R/dewPoint.R
calcDewPoint.A.Rd
The following formula is used for dew point estimation: $$ (RH/100 )^(1/8) * (110+temp) -110) $$ ,where RH is relative humidity and temp is ambient temperature. The formula was taken from this wikipedia page: <https://es.wikipedia.org/wiki/Punto_de_roc
calcDewPoint.A(RH, temp)
RH | [in percentage] relative humidity, an integer or double value between 0 and 100. |
---|---|
temp | [°C] environmental temperature, an integer or double value between -20 and 60 °C |
dew point value (double)
#> [1] 14.99222